• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS 60137:2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

19-06-2008

Superseded date

15-05-2020

Superseded by

AS/NZS 60137:2020

£80.28
Excluding VAT

1 - AS/NZS 60137:2008 Insulated bushings for alternating voltages above 1000 V
4 - PREFACE
5 - CONTENTS
7 - INTRODUCTION
9 - 1 Scope
9 - 2 Normative references
11 - 3 Terms and definitions
16 - 4 Ratings
16 - 4.1 Standard values of highest voltage for equipment (Um)
16 - 4.2 Standard values of rated current (Ir)
17 - 4.3 Standard values of rated thermal short-time current (Ith)
17 - 4.4 Standard values of rated dynamic current (Id)
17 - 4.5 Minimum withstand values of cantilever load
17 - 4.6 Angle of mounting
17 - 4.7 Minimum nominal creepage distance
18 - 4.8 Temperature limits and temperature rise
18 - 4.9 Standard insulation levels
19 - 4.10 Test tap on transformer bushings
19 - 5 Operating conditions
19 - 5.1 Temporary overvoltages
19 - 5.2 Altitude
20 - 5.3 Temperature of ambient air and immersion media
20 - 5.4 Seismic conditions
20 - 6 Ordering information and markings
20 - 6.1 Enumeration of characteristics
22 - 6.2 Markings
22 - 7 Test requirements
22 - 7.1 General requirements
23 - 7.2 Test classification
24 - 7.3 Condition of bushings during dielectric and thermal tests
24 - 8 Type tests
25 - 8.1 Dry or wet power-frequency voltage withstand test
25 - 8.2 Dry lightning impulse voltage withstand test (BIL)
26 - 8.3 Dry or wet switching impulse voltage withstand test (SIL)
27 - 8.4 Thermal stability test
28 - 8.5 Temperature rise test
30 - 8.6 Verification of thermal short-time current withstand
31 - 8.7 Cantilever load withstand test
32 - 8.8 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings
32 - 8.9 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings
32 - 8.10 External pressure test on partly or completely gas-immersed bushings
33 - 8.11 Verification of dimensions
33 - 9 Routine tests
33 - 9.1 Measurement of dielectric dissipation factor (tan δ) and capacitance at ambient temperature
34 - 9.2 Dry lightning impulse voltage withstand test (BIL)
34 - 9.3 Dry power-frequency voltage withstand test
35 - 9.4 Measurement of partial discharge quantity
35 - 9.5 Tests of tap insulation
36 - 9.6 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings
36 - 9.7 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings
36 - 9.8 Tightness test on gas-filled, gas-insulated and gas-impregnated bushings
37 - 9.9 Tightness test at the flange or other fixing device
38 - 9.10 Visual inspection and dimensional check
38 - 10 Requirements and tests for bushings of highest voltages for equipment equal to or less than 52 kV made of ceramic, glass or inorganic materials, resin or combined insulation
38 - 10.1 Temperature requirements
38 - 10.2 Level of immersion medium
38 - 10.3 Markings
39 - 10.4 Test requirements
50 - Bibliography
51 - Annex ZA (normative) Radio influence voltage (RIV) test
52 - Annex ZZ (normative) Variations to IEC 60137, Ed. 5.0 (2003) for application in Australia and New Zealand
55 - Annex ZA (normative) Radio influence voltage (RIV) test

Specifies the characteristics and tests for insulated bushings for electrical equipment with a voltage above 1000 volt a.c. and a nominal frequency in the range 15-60 Hz.

Committee
EL-008
DocumentType
Standard
ISBN
0 7337 8713 4
Pages
47
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Originated as AS 1265-1990.
Jointly revised and redesignated as AS/NZS 60137:2008.

AS 60038-2000 Standard voltages
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 60270-2001 High-voltage test techniques - Partial discharge measurements
AS 2374.5-1982 Power Transformers Ability To Withstand Short-Circuit
AS 1824.1-1995 Insulation co-ordination Definitions, principles and rules
AS/NZS 1052:1992 CISPR specification for radio interference measuring apparatus and measurement methods
AS 3768-1990 Guide to the effects of temperature on electrical equipment
AS 2650-2005 Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD)
AS 60068.2.17-2003 Environmental testing Tests - Test Q: Sealing
AS IEC 62155-2005 Insulators - Ceramic or glass - Hollow pressurized and unpressurized - Voltages greater than 1000 V a.c.
AS 2374.7-1997 Power transformers Loading guide for oil-immersed power transformers
AS 4436-1996 Guide for the selection of insulators in respect of polluted conditions

AS/NZS 60076.1:2014 Power transformers General (IEC 60076-1, Ed. 3.0 (2011) MOD)
AS/NZS 60076.6:2013 Power transformers Reactors
AS 62271.203-2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

£80.28