Standard Practice for Calibration of Thin Heat Flux Transducers
15-10-2021
English
01-09-2017
CONTAINED IN VOL. 04.06, 2017 Defines procedures for the calibration of heat flux transducers that are dimensionally thin in comparison to their planar dimensions.
Committee |
C 16
|
DocumentType |
Redline
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This practice, in conjunction with either Test Method C177, C518, C1114, or C1363, establishes procedures for the calibration of heat flux transducers that are dimensionally thin in comparison to their planar dimensions.
1.1.1 The thickness of the heat flux transducer shall be less than 30 % of the narrowest planar dimension of the heat flux transducer.
1.2This practice describes techniques for determining the sensitivity, S, of a heat flux transducer when subjected to one dimensional heat flow normal to the planar surface or when installed in a building application.
1.3This practice shall be used in conjunction with Practice C1046 and Practice C1155 when performing in-situ measurements of heat flux on opaque building components. This practice is comparable, but not identical, to the calibration techniques described in ISO 9869-1.
1.4This practice is not intended to determine the sensitivity of heat flux transducers used as components of heat flow meter apparatus, as in Test Method C518, or used for in-situ industrial applications, as covered in Practice C1041.
1.5The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.6Units—The values stated in SI units are to be regarded as standard. The values given in parentheses are provided for information only and are not considered standard.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1155 : 1995 | Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data |
ASTM C 1470 : 2006 | Standard Guide for Testing the Thermal Properties of Advanced Ceramics |
DD ISO/TS 14934-4:2007 | Fire tests. Calibration of heat flux meters Guidance on the use of heat flux meters in fire tests |
ASTM C 1046 : 1995 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1155 : 1995 : R2007 | Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data |
ISO/TS 14934-4:2007 | Fire tests Calibration of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests |
ASTM C 1046 : 1995 : R2013 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
BS ISO 14934-4:2014 | Fire tests. Calibration and use of heat flux meters Guidance on the use of heat flux meters in fire tests |
ASTM C 1046 : 1995 : R2001 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1046 : 1995 : R2007 | Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components |
ASTM C 1155 : 1995 : R2013 | Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data |
ASTM C 1363 : 2011 : REDLINE | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM E 2684 : 2017 : REDLINE | Standard Test Method for Measuring Heat Flux Using Surface-Mounted One-Dimensional Flat Gages |
ASTM C 1470 : 2006 : R2013 | Standard Guide for Testing the Thermal Properties of Advanced Ceramics |
13/30292037 DC : 0 | BS ISO 14934-4 - FIRE TESTS - CALIBRATION OF HEAT FLUX METERS - PART 4: GUIDANCE ON THE USE OF HEAT FLUX METERS IN FIRE TESTS |
ASTM C 1155 : 1995 : R2001 | Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data |
ISO 14934-4:2014 | Fire tests Calibration and use of heat flux meters Part 4: Guidance on the use of heat flux meters in fire tests |
ASTM C 518 : 2017 : REDLINE | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ISO 9869-1:2014 | Thermal insulation Building elements In-situ measurement of thermal resistance and thermal transmittance Part 1: Heat flow meter method |
ASTM C 1363 : 2011 : REDLINE | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1044 : 2016 : REDLINE | Standard Practice for Using a Guarded-Hot-Plate Apparatus or Thin-Heater Apparatus in the Single-Sided Mode |
ASTM C 168 : 2017-06 | TERMINOLOGY RELATING TO THERMAL INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.