• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

CLC/TR 50481:2009

Current

Current

The latest, up-to-date edition.

Recommendations on filters for shielded enclosures

Published date

17-04-2009

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 General recommendations on filters
5 Insertion loss
   5.1 Insertion loss of filters
   5.2 Insertion loss values
6 Filter selection
   6.1 Choice of filter
   6.2 Power line filters
   6.3 Signal line filters (including telecom lines)
7 Electrical safety
8 Installation of filters
Bibliography

This document was prepared to give users general advices on filtering solutions adopted in shielded enclosures. It is mainly a collection of hints derived from practical experience. This document is coordinated with EN 50147-1 and EN 50417-2. The document covers the frequency range DC to 40 GHz. The range above 40 GHz and up to 400 GHz is under consideration.

Committee
CLC/TC 210
DevelopmentNote
Supersedes R210-004. (07/2009)
DocumentType
Technical Report
PublisherName
European Committee for Standards - Electrical
Status
Current
Supersedes

Standards Relationship
PD CLC/TR 50481:2009 Identical
CEI CLC/TR 50481 : 2010 Identical
NEN NPR CLC/TR 50481 : 2009 Identical

CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
I.S. EN 55016-1-4:2010 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS
BS EN 55016-1-4 : 2010 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
UNE-EN 55016-1-4:2011 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements

EN 50147-1:1996 Anechoic chambers - Part 1: Shield attenuation measurement
EN 50147-2 : 1996 ANECHOIC CHAMBERS - PART 2: ALTERNATIVE TEST SITE SUITABILITY WITH RESPECT TO SITE ATTENUATION
CISPR 17:2011 Methods of measurement of the suppression characteristics of passive EMC filtering devices

Sorry this product is not available in your region.