Summarise this standard

1 Scope
2 Normative references
3 Definitions - Terms and abbreviations
4 Overview of the methodology
  4.1 Measurement techniques
  4.2 Methodology in case of complaint
5 Selection of measurement location and general condition
  5.1 General
  5.2 Frequency range up to 30 MHz
  5.3 Frequency range above 30 MHz
  5.4 Emission measurements in the presence of ambient signal
6 Measurement of conducted emissions
  6.1 Disturbance below 9 kHz
  6.2 Disturbance in the frequency range 9 kHz to 30 MHz
7 Measurement of radiated emissions
  7.1 General
  7.2 Frequency range above 9 kHz
  7.3 Field strength specific indoors measurement
  7.4 Radiated disturbance power in the frequency range above 30 MHz
8 Measurement report
Annex A (informative) Investigation in case of complaint
  A.1 Identification of the interference
  A.2 Evaluation of the victim and characterisation of the
      source of interference
  A.3 Evaluation of results
Annex B (informative) Protection of radio communications services
  B.1 Radio services
  B.2 Safety services
Annex C (informative) Measurement techniques
  C.1 Rationale for excluding compliance testing
  C.2 Measurement distance below 3 m
  C.3 Active dipole
Annex D (informative) Low frequency phenomena
  D.1 Measurement techniques for low frequency (below 9 kHz)
  D.2 Disturbance emission from mains, or other power circuits
  D.3 Measurement of conducted emissions
  D.4 Radiated emission in the frequency range up to 9 kHz
Bibliography

This guide describes analysis methods of disturbance emission to be applied in situ for identification of the disturbance source and resolution of complaint. Where applicable, the methods rely on already published documents either in CENELEC or in IEC. It is not intended to be used for type testing or any kind of conformity assessment. Dealing with effects on living matter is excluded from this document. The frequency range of interest is from d.c. to 400 GHz. This document applies for analysing an interference complaint. It provides method for identification and characterisation in situ of the source(s) of interference. It proposes procedures to discriminate different kind of sources. Reference in situ measurement distances are defined. It allows comparison of the results and of technical characteristics of the interfered equipment with existing relevant standards. The result of the comparison is intended to help in the resolution of the complaint. It is meant for verifying the emissions from fixed installations whatever equipment they contain, and whatever have been the type tests of these equipment. It may be used to describe the coupling path for interference between the victim and the source, and to compare the measurement results with the limits from the adequate standard, at a specific location and in a given frequency band.