• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

CLC/TS 50549-2:2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Requirements for generating plants to be connected in parallel with distribution networks - Part 2: Connection to a MV distribution network

Published date

16-01-2015

Withdrawn date

10-03-2023

Sorry this product is not available in your region.
Summarise this standard

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements on generating plants
5 Conformance test procedure
Annex A (informative) - Interconnection requirements
Annex B (informative) - Remote information exchange
Annex C (informative) - Frequency stabilizing services
Annex D (informative) - Loss of Mains and overall power
        system security
Annex E (informative) - Examples of protection strategies
Annex F (normative) - Abbreviations
Bibliography

The purpose of this Technical Specification is to provide technical guidance on the requirements for generating plants which can be operated in parallel with a distribution network.For practical reasons, this Technical Specification refers to the distribution system operator in case settings have to be defined and/or provided, even when these settings are to be defined and/or provided by another actor according to national and European legal framework. NOTE 1This includes European network codes and their national implementation, as well as further national regulations.NOTE 2Further national requirements especially for the connection to the distribution network and the operation of the generating plant can apply.The requirements of this Technical Specification apply to all generating plants, electrical machinery and electronic equipment, irrespective of the kind of primary energy source and irrespective of the presence of loads in the producer’s network that meet all of the following conditions:-converting any primary energy source into AC electricity;-connected to a MV distribution network;-intended to operate in parallel with this distribution network under normal network operating conditions. NOTE 3Generating plants connected to a LV distribution network fall into the scope of EN 50438 (up to 16 A) and CLC/TS 50549-1 (above 16 A).Unless stated differently by the DSO, a generating plant with a maximum apparent power up to 100 kVA can, as alternative to the requirements of this Technical Specification, comply with CLC/TS 50549-1. A different threshold may be defined by the DSO.This Technical Specification defines connection requirements.This Technical Specification recognizes the existence of National Standards, Network Codes, and specific technical requirements of the DSOs. These should be complied with. Excluded from the scope are:-the selection and evaluation of the point of connection;-power system impact assessment;-connection assessment;-island operation of generating plants, both intentional and unintentional, where no part of the distribution network is involved;-active front ends of drives feeding energy back into the distribution network for short duration;-requirements for the safety of personnel as they are already adequately covered by existing European Standards.

Committee
CLC/TC 8X
DocumentType
Technical Specification
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn
SupersededBy

Sorry this product is not available in your region.