• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EI SAFE HANDLING STORAGE BIOMASS TPS : 1ED 2016

Current

Current

The latest, up-to-date edition.

SAFE HANDLING AND STORAGE OF BIOMASS IN THERMAL POWER STATIONS

Published date

11-04-2016

Sorry this product is not available in your region.

Acknowledgements
Foreword
1 Introduction
2 Types and supply of biomass
3 Hazardous properties
4 Properties during handling
5 Handling and storage
6 Learning from experience
7 Implementing safe design
8 Prevention
9 Fire, gas detection and means of escape
10 Explosion precautions
11 Fire control
12 Operating procedures
13 Relevant legislation
14 Contents of a DSEAR risk assessment
15 Contents of a fire risk assessment
Annexes
Annex A - Glossary of terms and acronyms
Annex B - References and literature review
Annex C - Major incident review

Specifies information and guidance for the safe on-site handling and storage of biomass material suitable for burning in thermal power stations.

DocumentType
Standard
PublisherName
Energy Institute (formerly Institute of Petroleum - IP)
Status
Current

BS EN 14961-2:2011 Solid biofuels. Fuel specifications and classes Wood pellets for non-industrial use
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
BS EN 15297:2011 Solid biofuels. Determination of minor elements. As, Cd, Co, Cr, Cu, Hg, Mn, Mo, Ni, Pb, Sb, V and Zn
BS EN 12882:2015 Conveyor belts for general purpose use. Electrical and flammability safety requirements
BS EN 14797:2006 Explosion venting devices
BS EN 14778:2011 Solid biofuels. Sampling
BS EN ISO 340:2013 Conveyor belts. Laboratory scale flammability characteristics. Requirements and test method
BS EN 15089:2009 Explosion isolation systems
NFPA 850 : 2015 FIRE PROTECTION FOR ELECTRIC GENERATING PLANTS AND HIGH VOLTAGE DIRECT CURRENT CONVERTER STATIONS
BS EN 50281-2-1:1999 Electrical apparatus for use in the presence of combustible dust. Test methods Methods of determining minimum ignition temperatures
BS EN 15188:2007 Determination of the spontaneous ignition behaviour of dust accumulations
BS EN 13821:2002 Potentially explosive atmospheres. Explosion prevention and protection. Determination of minimum ignition energy of dust/air mixtures
BS EN 14034-1 : 2004 DETERMINATION OF EXPLOSION CHARACTERISTICS OF DUST CLOUDS - PART 1: DETERMINATION OF THE MAXIMUM EXPLOSION PRESSURE P[MAX] OF DUST CLOUDS
BS EN 15359:2011 Solid recovered fuels. Specifications and classes
BS EN 1755:2015 Industrial Trucks. Safety requirements and verification. Supplementary requirements for operation in potentially explosive atmospheres
BS EN 16447:2014 Explosion isolation flap valves
BS EN 12881-2 : 2005 CONVEYOR BELTS - FIRE SIMULATION FLAMMABILITY TESTING - PART 2: LARGE SCALE FIRE TEST
BS EN 60079-10-2:2015 Explosive atmospheres Classification of areas. Explosive dust atmospheres
BS EN 14034-2 : 2006 DETERMINATION OF EXPLOSION CHARACTERISTICS OF DUST CLOUDS - PART 2: DETERMINATION OF THE MAXIMUM RATE OF EXPLOSION PRESSURE RISE (DP/DT)[MAX] OF DUST CLOUDS
NFPA 15 : 2017 WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION
EN 60079-31:2014 Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
PD CLC/TR 60079-32-1:2015 Explosive atmospheres Electrostatic hazards, guidance
NFPA 68 : 2013 EXPLOSION PROTECTION BY DEFLAGRATION VENTING
BS EN 1554:2012 Conveyor belts. Drum friction testing
BS EN 14034-3 : 2006 DETERMINATION OF EXPLOSION CHARACTERISTICS OF DUST CLOUDS - PART 3: DETERMINATION OF THE LOWER EXPLOSION LIMIT LEL OF DUST CLOUDS
BS EN 12881-1:2014 Conveyor belts. Fire simulation flammability testing Propane burner tests
BS EN 13463-1:2009 Non-electrical equipment for use in potentially explosive atmospheres Basic method and requirements
PD CEN/TR 15281:2006 Guidance on inerting for the prevention of explosions
BS EN 14034-4 : 2004 DETERMINATION OF EXPLOSION CHARACTERISTICS OF DUST CLOUDS - PART 4: DETERMINATION OF THE LIMITING OXYGEN CONCENTRATION LOC OF DUST CLOUDS
BS EN 60079-11:2012 Explosive atmospheres Equipment protection by intrinsic safety \'i\'
EN 60079-14:2014/AC:2016 EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016)
BS EN 14491:2012 Dust explosion venting protective systems
BS EN 14961-1:2010 Solid biofuels. Fuel specifications and classes General requirements
BS EN 13463-5:2011 Non-electrical equipment intended for use in potentially explosive atmospheres Protection by constructional safety \'c\'
BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
BS IEC 61882:2001 Hazard and operability studies (HAZOP studies). Application guide
BS EN 1127-1:2011 Explosive atmospheres. Explosion prevention and protection Basic concepts and methodology
BS EN 15210-1:2009 Solid biofuels. Determination of mechanical durability of pellets and briquettes Pellets
BS EN 13478 : 2002 SAFETY OF MACHINERY - FIRE PREVENTION AND PROTECTION

Sorry this product is not available in your region.