I.S. EN 60580:2000
Superseded
View Superseded by
MEDICAL ELECTRICAL EQUIPMENT - DOSE AREA PRODUCT METERS
Hardcopy , PDF
English
01-01-2000
30-04-2020
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terminology and definitions
4 General requirements
4.1 Performance requirements
4.2 Minimum EFFECTIVE RANGES of DOSE AREA PRODUCT and DOSE
AREA PRODUCT RATE
4.3 Plane of measurement
4.4 REFERENCE VALUES and STANDARD TEST CONDITIONS
4.5 General test conditions
4.5.1 STANDARD TEST CONDITIONS
4.5.2 Test of components
4.5.3 STABILIZATION TIME
4.5.4 Adjustments during test
4.5.5 Uniformity of radiation field
4.6 Statistical fluctuations
4.7 Uncertainty of measurement
4.8 Constructional requirements as related to performance
4.8.1 Display
4.8.2 Indication of polarizing voltage failure
4.8.3 Over-ranging
4.8.4 Indication of reset or other inactive condition
4.8.5 IONIZATION CHAMBER
4.9 STABILITY CHECK DEVICE
4.10 Adjustment
4.11 Electrical safety
5 Limits of PERFORMANCE CHARACTERISTICS under STANDARD TEST
CONDITIONS
5.1 RELATIVE INTRINSIC ERROR
5.2 Warning function
5.3 Repeatability
5.4 RESOLUTION of reading
5.5 STABILIZATION TIME
5.6 Reset on DOSE AREA PRODUCT ranges
5.7 Drift of INDICATED VALUES
5.8 Long term stability
5.9 RESPONSE TIME
5.10 Spatial uniformity of RESPONSE
6 LIMITS OF VARIATION for effects of INFLUENCE QUANTITIES
6.1 Energy dependence of RESPONSE
6.2 DOSE AREA PRODUCT RATE dependence of DOSE AREA PRODUCT
measurements
6.2.1 MEASURING ASSEMBLY
6.2.2 IONIZATION CHAMBER - Recombination losses
6.3 IRRADIATION TIME
6.4 Field size
6.5 Operating voltage
6.6 Air pressure
6.7 Temperature and humidity
6.8 Air density fluctuation in the IONIZATION CHAMBER
6.9 Electromagnetic compatibility
6.9.1 General
6.9.2 Electrostatic discharge
6.9.3 Radiated electromagnetic fields
6.9.4 Conducted disturbances induced by bursts and high
frequencies
6.9.5 Surges
6.9.6 Voltage dips, short interruptions and voltage
VARIATIONS
6.10 COMBINED STANDARD UNCERTAINTY
7 Marking
7.1 MEASURING ASSEMBLY
7.2 IONIZATION CHAMBER
8 ACCOMPANYING DOCUMENTS
Bibliography
Index of defined terms
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Defines the performance and testing of DOSE AREA PRODUCT METERS with IONIZATION CHAMBERS intended to measure DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS.
| DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
| DocumentType |
Standard
|
| Pages |
44
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| BS EN 60580:2000 | Identical |
| NF EN 60580 : 2004 | Identical |
| EN 60580:2000 | Identical |
| IEC 60580:2000 | Identical |
| NBN EN 60580 : 2001 | Identical |
| DIN EN 60580:2001-12 | Identical |
| UNE-EN 60580:2001 | Identical |