IEC 60580:2000
Superseded
View Superseded by
Medical electrical equipment - Dose area product meters
Hardcopy , PDF
English, English - French
14-01-2000
31-12-2021
Foreword
Introduction
1. Scope and object
2. Normative references
3. Terminology and definitions
4. General requirements
4.1 Performance requirements
4.2 Minimum EFFECTIVE RANGES of DOSE AREA PRODUCT
and DOSE AREA PRODUCT RATE
4.3 Plane of measurement
4.4 REFERENCE VALUES and STANDARD TEST CONDITIONS
4.5 General test conditions
4.5.1 STANDARD TEST CONDITIONS
4.5.2 Test of components
4.5.3 STABILIZATION TIME
4.5.4 Adjustments during test
4.5.5 Uniformity of radiation field
4.6 Statistical fluctuations
4.7 Uncertainty of measurement
4.8 Constructional requirements as related to performance
4.8.1 Display
4.8.2 Indication of polarizing voltage failure
4.8.3 Over-ranging
4.8.4 Indication of reset or other inactive condition
4.8.5 IONIZATION CHAMBER
4.9 STABILITY CHECK DEVICE
4.10 Adjustment
4.11 Electrical safety
5. Limits of PERFORMANCE CHARACTERISTICS under STANDARD TEST
CONDITIONS
5.1 RELATIVE INTRINSIC ERROR
5.2 Warning function
5.3 Repeatability
5.4 RESOLUTION of reading
5.5 STABILIZATION TIME
5.6 Reset on DOSE AREA PRODUCT ranges
5.7 Drift of INDICATED VALUES
5.8 Long term stability
5.9 RESPONSE TIME
5.10 Spatial uniformity of RESPONSE
6. LIMITS OF VARIATION for effects of INFLUENCE QUANTITIES
6.1 Energy dependence of RESPONSE
6.2 DOSE AREA PRODUCT RATE dependence of DOSE AREA PRODUCT
measurements
6.2.1 MEASURING ASSEMBLY
6.2.2 IONIZATION CHAMBER - Recombination losses
6.3 IRRADIATION TIME
6.4 Field size
6.5 Operating voltage
6.6 Air pressure
6.7 Temperature and humidity
6.8 Air density fluctuation in the IONIZATION CHAMBER
6.9 Electromagnetic compatibility
6.9.1 General
6.9.2 Electrostatic discharge
6.9.3 Radiated electromagnetic fields
6.9.4 Conducted disturbances induced by bursts and
high frequencies
6.9.5 Surges
6.9.6 Voltage dips, short interruptions and voltage
VARIATIONS
6.10 COMBINED STANDARD UNCERTAINTY
7. Marking
7.1 MEASURING ASSEMBLY
7.2 IONIZATION CHAMBER
8. ACCOMPANYING DOCUMENTS
Table 1 - Minimum EFFECTIVE RANGES
Table 2 - REFERENCE VALUES and STANDARD TEST CONDITIONS
Table 3 - Number of readings required to detect true
differences delta (95 % confidence level) between
two sets of instrument readings
Table 4 - RELATIVE INTRINSIC ERROR, iota
Table 5 - Maximum values for the COEFFICIENT OF VARIATION Vmax
Table 6 - LIMITS OF VARIATION for the effects of INFLUENCE
QUANTITIES
Table 7 - Example for assessment of the COMBINED STANDARD
UNCERTAINTY
Bibliography
Index of defined terms
Specifies the performance and testing of dose area product meters with ionization chambers intended to measure dose area product and/or dose area product rate to which the patient is exposed during medical radiological examinations.The object of this International Standard is1) to establish requirements for a satisfactory level of performance for dose area product meters, and2) to standardize the methods for the determination of compliance with this level of performance.
| Committee |
TC 62/SC 62C
|
| DevelopmentNote |
Also numbered as BS EN 60580. (10/2005) Stability Date: 2018. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
32
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| NF EN 60580 : 2004 | Identical |
| GOST IEC 60580 : 2011 | Identical |
| HD 379 : 200S1 | Identical |
| NEN EN IEC 60580 : 2000 | Identical |
| NEN 10580 : 1978 | Identical |
| I.S. EN 60580:2000 | Identical |
| PN EN 60580 : 2002 | Identical |
| AS/NZS 4957:2002 | Identical |
| CEI EN 60580 : 2001 | Identical |
| CEI 62-7 : 1ED 1998 | Identical |
| EN 60580:2000 | Identical |
| DIN EN 60580:2001-12 | Identical |
| UNE 20610:1979 | Identical |
| UNE-EN 60580:2001 | Identical |
| GOST R IEC 60580 : 2006 | Identical |