1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
APPENDIX A - PROCEDURE FOR QUALIFICATION INSPECTION

Describes the general requirements for established reliability (ER) and non-ER, aluminum oxide, electrolytic, fixed capacitors.

DevelopmentNote
Supersedes MIL C 39018 (B) (09/2004) New child NOT 1 2022 is added.
DocumentType
Standard
Pages
72
ProductNote
New child NOT 1 2022 is added.
PublisherName
US Military Specs/Standards/Handbooks
Status
Current
Supersedes

This specification covers the general requirements for established reliability (ER) and non-ER, aluminum oxide, electrolytic, fixed capacitors (see 6.1). Capacitors meeting the ER requirements of this specification have reliability established on the basis of life tests performed at rated voltage at +85°C for failure rate (FR) levels ranging from 1.0 percent to 0.001 percent per 1,000 hours in accordance with MIL-STD-690. These FR levels are established at a 60-percent confidence level and are maintained at a 10 percent producer\'s risk. The level of reliability is identified by the following FR level symbols:

MIL-PRF-39018-3 Revision G:2009 Capacitor, Fixed, Electrolytic (Aluminum Oxide) (Polarized), Non-Established Reliability and Established Reliability, Styles CU16 (Uninsulated), CU17 (Insulated), and CUR17 (Insulated)
DSCC 89085 : E#CAN CAPACITORS, FIXED, ELECTROLYTIC, POLARIZED, ALUMINIUM OXIDE, SNAP MOUNT, LOW PROFILE
MIL STD 11991 : A GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES
MIL-PRF-39018-4 Revision E:2009 Capacitor, Fixed, Electrolytic (Aluminum Oxide) (Polarized), Non-Established Reliability and Established Reliability, Styles CU71 (Insulated) and CUR71 (Insulated)
MIL HDBK 1131 : C STORAGE SHELF LIFE AND REFORMING PROCEDURES FOR ALUMINUM ELECTROLYTIC FIXED CAPACITORS
DSCC 05018 : F CAPACITOR, ULTRA LONG LIFE, ALUMINUM CASE FLAT PACK, +85 DEGREES C
DSCC 89021 : E CAPACITORS, FIXED, ELECTROLYTIC, POLARIZED, ALUMINIUM OXIDE, ULTRA-LOW ESR
MIL-PRF-39018-1 Revision H:2009 Capacitor, Fixed, Electrolytic (Aluminum Oxide) (Polarized), Non-Established Reliability and Established Reliability, Styles CU12 (Uninsulated), CU13 (Insulated), and CUR13 (Insulated)
DSCC 01001 : A CAPACITORS, FIXED, ELECTROLYTIC, POLARIZED, ALUMINUM OXIDE
MIL-PRF-39018-2 Revision F:2009 Capacitor, Fixed, Electrolytic (Aluminum Oxide) (Nonpolarized), Styles CU14 (Uninsulated) and CU15 (Insulated)
DSCC 05019 : G CAPACITOR, ULTRA LONG LIFE, STAINLESS-STEEL CASE FLAT PACK, +125 DEGREES C
MIL C 39018/10 : B CAPACITORS, FIXED, ELECTROLYTIC (ALUMINUM OXIDE)(POLARIZED), ESTABLISHED RELIABILITY, STYLE CUR92 (INSULATED)
MIL-PRF-39018-7 Revision C:2009 Capacitor, Fixed, Electrolytic (Aluminum Oxide) (Polarized), (Four-Terminal), Established Reliability, Style CUR19 (Insulated)
DSCC 88022 : F CAPACITORS, FIXED, ELECTROLYTIC, POLARIZED, ALUMINIUM OXIDE, SINGLE END MOUNTING
MIL-HDBK-198 Revision B:2012 Capacitors, Selection and Use of
DSCC 89012 : C CAPACITORS, FIXED, ELECTROLYTIC, POLARIZED, ALUMINIUM OXIDE, LOW SCREW-INSERT
MIL-PRF-39018-6 Revision D:2009 Capacitor, Fixed, Electrolytic (Aluminum Oxide) (Polarized), Established Reliability, Style CUR91 (Insulated)

MIL-STD-202-211 Base Document:2015 Method 211, Terminal Strength
MIL-STD-202-302 Base Document:2015 Method 302, Insulation Resistance
MIL-STD-810 Revision G:2008 ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS
MIL-STD-1276 Revision H:2013 Leads for Electronic Component Parts
MIL-STD-202-305 Base Document:2015 Method 305, Capacitance
MIL-STD-202-101 Base Document:2015 Method 101, Salt Atmosphere (Corrosion)
MIL-STD-202-107 Base Document:2015 Method 107, Thermal Shock
MIL-STD-202-106 Base Document:2015 Method 106, Moisture Resistance
MIL-STD-202-301 Base Document:2015 Method 301, Dielectric Withstanding Voltage
MIL-STD-790 Revision G:2011 Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications
MIL-STD-202-104 Base Document:2015 Method 104, Immersion
MIL-STD-202-108 Base Document:2015 Method 108, Life (at Elevated Ambient Temperature)
MIL-STD-202-105 Base Document:2015 Method 105, Barometric Pressure (Reduced)
MIL-STD-202-208 Base Document:2015 Method 208, Solderability
MIL-STD-202 Revision H:2015 Electronic and Electrical Component Parts
MIL-STD-1285 Revision D:2004 Marking of Electrical and Electronic Parts
FED-STD-H28 Revision A:1994 Screw-Thread Standards for Federal Services
MIL-STD-202-201 Base Document:2015 Method 201, Vibration
MIL-STD-202-214 Base Document:2015 Method 214, Random Vibration
MIL-STD-690 Revision D:2005 Failure Rate (FR) Sampling Plans and Procedures
MIL-STD-202-204 Base Document:2015 Method 204, Vibration, High Frequency
MIL-STD-202-213 Base Document:2015 Method 213, Shock (Specified Pulse)

£13.91
Excluding VAT