• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

PREN 13830 : DRAFT 2013

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

CURTAIN WALLING - PRODUCT STANDARD

Published date

19-06-2013

Superseded date

01-04-2015

Superseded by

EN 13830:2015

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
  performance - AVCP
7 Marking, labelling
Annex A (informative) - Example of curtain walling types:
        pictures and schemes
Annex B (informative) - Maintenance
Annex C (informative) - Equipotential bonding conditions
Annex D (informative) - Resistance to actions: guidance on
        the use of Eurocodes
Annex E (informative) - Resistance to seismic action
Annex F (normative) - Selection, preparation, mounting and
        fixing of test specimen for reaction to fire tests
        of curtain walling and field of direct application
Annex G (informative) - Characteristics and range of direct
        application
Annex H (informative) - Requirements and performances of
        curtain walling kit
Annex I (informative) - Interchangeability between characteristics
        and components
Annex J (informative) - Basic approach to durability
Annex ZA (informative) - Clauses of this standard addressing the
         provisions of the EU Construction Product Regulation
Bibliography

Defines requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and environmental control and gives test/assessments/calculation methods and compliance criteria of the related performances.

Committee
TC 33
DocumentType
Draft
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
13/30281348 DC : 0 Identical

EN 12152:2002 Curtain walling - Air permeability - Performance requirements and classification
EN 13051:2001 Curtain Walling - Watertightness - Site test
DIN EN 12152:2002-08 Curtain walling - Air permeability - Performance requirements and classification
EN 12153:2000 Curtain walling - Air permeability - Test method
I.S. EN 12153:2000 CURTAIN WALLING - AIR PERMEABILITY - TEST METHOD
I.S. EN 12152:2002 CURTAIN WALLING - AIR PERMEABILITY - PERFORMANCE REQUIREMENTS AND CLASSIFICATION
ENV 13050:2000 Curtain walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray
DD ENV 13050:2001 Curtain walling. Watertightness. Laboratory test under dynamic condition of air pressure and water spray
BS EN 13116:2001 Curtain walling. Resistance to wind load. Performance requirements
BS EN 12155:2000 Curtain walling. Watertightness. Laboratory test under static pressure
BS EN 12153:2000 Curtain walling. Air permeability. Test method
BS EN 13051:2001 Curtain walling. Watertightness. Site test
BS EN 12152:2002 Curtain walling. Air permeability. Performance requirements and classification
03/100998 DC : DRAFT MAR 2003 EN 13022-3 - GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 3: ASSEMBLY RULES
EN 12155:2000 Curtain walling - Watertightness - Laboratory test under static pressure
EN 13116:2001 Curtain walling - Resistance to wind load - Performance requirements
I.S. EN 13116:2001 CURTAIN WALLING - RESISTANCE TO WIND LOAD - PERFORMANCE REQUIREMENTS

EN 13051:2001 Curtain Walling - Watertightness - Site test
EN 13022-1:2014 Glass in building - Structural sealant glazing - Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing
EN 13168:2012+A1:2015 Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification
ISO 140-5:1998 Acoustics — Measurement of sound insulation in buildings and of building elements — Part 5: Field measurements of airborne sound insulation of façade elements and façades
EN 12153:2000 Curtain walling - Air permeability - Test method
EN 14509:2013 Self-supporting double skin metal faced insulating panels - Factory made products - Specifications
EN 13116:2001 Curtain walling - Resistance to wind load - Performance requirements
EN 13050:2011 Curtain Walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray
EN 1364-3:2014 Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly)
EN 1096-4:2004 Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard
EN ISO 9046:2004 Building construction - Jointing products - Determination of adhesion/cohesion properties of sealants at constant temperature (ISO 9046:2002)
EN 12758:2011 Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
EN 13164:2012+A1:2015 Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification
EN 15434:2006+A1:2010 Glass in building - Product standard for structural and/or ultra-violet resistant sealant (for use with structural sealant glazing and/or insulating glass units with exposed seals)
EN 15651-2:2017 Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing
EN ISO 12631:2017 Thermal performance of curtain walling - Calculation of thermal transmittance (ISO 12631:2017)
EN 13166:2012+A2:2016 Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 14019:2016 Curtain Walling - Impact resistance - Performance requirements
EN ISO 140-5:1998 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 5: Field measurements of airborne sound insulation of façade elements and façades (ISO 140-5:1998)
EN 12365-1:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 1: Performance requirements and classification
EN ISO 10591:2005 Building construction - Sealants - Determination of adhesion/cohesion properties of sealants after immersion in water (ISO 10591:2005)
EN 13823:2010+A1:2014 Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item
EN 15651-1:2017 Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1: Sealants for facade elements
EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
EN 13162:2012+A1:2015 Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
EN 13170:2012+A1:2015 Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification
EN 1279-4:2002 Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals
EN ISO 10848-1:2017 Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 1: Frame document (ISO 10848-1:2017)
ENV 13050:2000 Curtain walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray
EN ISO 10590:2005 Building construction - Sealants - Determination of tensile properties of sealants at maintained extension after immersion in water (ISO 10590:2005)
EN 12365-4:2003 Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 4: Recovery after accelerated ageing test method
EN 13165:2012+A2:2016 Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification
EN 1279-5:2005+A2:2010 Glass in building - Insulating glass units - Part 5: Evaluation of conformity
EN 1364-4:2014 Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration
EN 12155:2000 Curtain walling - Watertightness - Laboratory test under static pressure
EN 13171:2012+A1:2015 Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification
EN 12179:2000 Curtain walling - Resistance to wind load - Test method
EN 13167:2012+A1:2015 Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification
EN 1279-2:2002 Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration
EN 13119:2016 Curtain walling - Terminology
EN 13163:2012+A2:2016 Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification
EN ISO 8339:2005 Building construction - Sealants - Determination of tensile properties (Extension to break) (ISO 8339:2005)
EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
EN ISO 8340:2005 Building construction - Sealants - Determination of tensile properties at maintained extension (ISO 8340:2005)
EN 13169:2012+A1:2015 Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification
EN 13022-2:2014 Glass in building - Structural sealant glazing - Part 2: Assembly rules
EN 12152:2002 Curtain walling - Air permeability - Performance requirements and classification
EN 12154:1999 Curtain walling - Watertightness - Performance requirements and classification
EN 12600:2002 Glass in building - Pendulum test - Impact test method and classification for flat glass
EN 1096-2:2012 Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings
EN ISO 10848-2:2017 Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 2: Application to Type B elements when the junction has a small influence (ISO 10848-2:2017)