UNE-EN ISO 2719:2017

Current

Current

The latest, up-to-date edition.

Determination of flash point - Pensky-Martens closed cup method (ISO 2719:2016)

Available format(s)

Hardcopy , PDF

Published date

22-02-2017

£71.34
Excluding VAT

This International Standard describes three procedures, A, B and C, using the Pensky Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 °ðC to 370 °ðC.

CAUTION For certain mixtures no flash point, as defined, is observed; instead a significant enlargement of the test flame (not halo effect) and a change in colour of the test flame from blue to yellowish-orange can occur. Continued heating can result in significant burning of vapours outside the test cup, and can be a potential fire hazard.

NOTE 1Although, technically, kerosenes with a flash point above 40 °ðC can be tested using this International Standard, it is standard practice to test kerosenes according to ISO 13736 [3] . Similarly, lubricating oils are normally tested according to ISO 2592 [4].

Procedure A is applicable to distillate fuels (diesel, biodiesel blends, heating oil and turbine fuels), new and in-use lubricating oils, paints and varnishes, and other homogeneous liquids not included in the scope of Procedures B or C.

Procedure B is applicable to residual fuel oils, cutback residua, used lubricating oils, mixtures of liquids with solids, liquids that tend to form a surface film under test conditions or are of such kinematic viscosity that they are not uniformly heated under the stirring and heating conditions of Procedure A.

Procedure C is applicable to fatty acid methyl esters (FAME) as specified in specifications such as EN 14214 [5] or ASTM D 6751 [6].

This International Standard is not applicable to water-borne paints and varnishes.

NOTE 2Water-borne paints and varnishes can be tested using ISO 3679 [7]. Liquids containing traces of highly volatile materials can be tested using ISO 1523 [8] or ISO 3679.

Committee
CTN 51/SC 3
DevelopmentNote
Supersedes UNE EN 22719. (10/2003) Supersedes UNE 21320-18. (07/2004)
DocumentType
Standard
Pages
33
PublisherName
Asociación Española de Normalización
Status
Current

ISO 3171:1988 Petroleum liquids — Automatic pipeline sampling
ISO/TR 29662:2009 Petroleum products and other liquids — Guidance for flash point testing
ISO 3170:2004 Petroleum liquids — Manual sampling
CEN/TR 15138:2005 Petroleum products and other liquids - Guide to flash point testing
ISO Guide 33:2015 Reference materials — Good practice in using reference materials
ISO Guide 35:2017 Reference materials — Guidance for characterization and assessment of homogeneity and stability
ASTM E 2251 : 2014 : REDLINE Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids
ISO 3679:2015 Determination of flash no-flash and flash point — Rapid equilibrium closed cup method
ISO 15528:2013 Paints, varnishes and raw materials for paints and varnishes — Sampling
ISO 1523:2002 Determination of flash point — Closed cup equilibrium method
ISO 4259:2006 Petroleum products — Determination and application of precision data in relation to methods of test
IEC 60751:2008 Industrial platinum resistance thermometers and platinum temperature sensors
ISO 1513:2010 Paints and varnishes — Examination and preparation of test samples
ISO 13736:2013 Determination of flash point — Abel closed-cup method
ISO Guide 34:2009 General requirements for the competence of reference material producers
ASTM E 1137 : 1997 Standard Specification for Industrial Platinum Resistance Thermometers

£71.34