EN 60332-1-2:2004/A11:2016
Withdrawn
Withdrawn
View Superseded by
TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
Published date
01-12-2013
Withdrawn date
05-23-2019
Superseded by
Sorry this product is not available in your region.
European foreword
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Test apparatus
5 Procedure
6 Evaluation of test results
Annex A (informative) - Recommended performance requirements
Bibliography
Annex ZA (normative) - Normative references to International
publications with their corresponding European
publications
Covers the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions.
| Committee |
TC 20
|
| DevelopmentNote |
Supersedes EN 50265-2-1 (12/2004)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| ONORM OVE EN 60332-1-2 : 2017 | Identical |
| IEC 60332-1-2:2004+AMD1:2015 CSV | Identical |
| NBN EN 60332 1-2 : 2006 | Identical |
| NEN EN IEC 60332-1-2 : 2005 AMD 11 2016 | Identical |
| I.S. EN 60332-1-2:2004 | Identical |
| PN EN 60332-1-2 : 2010 AMD 11 2017 | Identical |
| VDE 0482-332-1-2 : 2017 | Identical |
| DIN EN 60332-1-2 : 2017 | Identical |
| BS EN 60332-1-2 : 2004 | Identical |
| NF EN 60332-1-2 : 2005 AMD 11 2017 | Identical |
| BS EN 60332-1-2:2004+A11:2016 | Identical |
| UNE-EN 60332-1-2:2005 | Identical |
| I.S. EN 45545-2:2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
| I.S. EN 13501-6:2014 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
| CEI UNI EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAUVIOR OF MATERIALS AND COMPONENTS |
| EN 45545-2:2013+A1:2015 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
| S.R. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
| I.S. EN 61010-1:2010 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
| DIN EN 13379:2016-06 (Draft) | PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS |
| DIN EN 13378:2016-05 (Draft) | PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS |
| EN 60695-9-2:2014 | Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods |
| EN 60695-1-10:2017 | Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
| EN 50264-2-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
| HD 60364-7-721:2009/corrigendum:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS |
| EN 60332-1-3:2004/A1:2015 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES (IEC 60332-1-3:2004/A1:2015) |
| DIN EN 13379:2013-05 | PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS |
| EN 50525-2-51:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation |
| HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
| EN 50525-2-31:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation |
| EN 13379:2001+A1:2013 | Pasta processing plants - Spreader, stripping and cutting machine, stick return conveyor, stick magazine - Safety and hygiene requirements |
| EN 50620:2017 | Electric cables - Charging cables for electric vehicles |
| EN 50575:2014/A1:2016 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
| BS EN 13501-6:2014 | Fire classification of construction products and building elements Classification using data from reaction to fire tests on electric cables |
| HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
| EN 50441-4:2012 | Cables for indoor residential telecommunication installations - Part 4: Cables up to 1 200 MHz - Grade 3 |
| EN 50525-2-72:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation |
| HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
| EN 50525-3-11:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
| EN 50441-1:2012 | Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1 |
| DIN EN 13378:2013-05 | PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS |
| HD 60364-7-717:2010/AC:2014 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS |
| EN 12601:2010 | Reciprocating internal combustion engine driven generating sets - Safety |
| HD 604 S1:1994/A3:2005 | 0.6/1 KV POWER CABLES WITH SPECIAL FIRE PERFORMANCE FOR USE IN POWER STATIONS |
| BS EN 50382-2 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
| EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
| BS EN 60332-1-3 : 2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES |
| BS EN 50620:2017 | Electric cables. Charging cables for electric vehicles (BT(DE/NOT)259) |
| EN 13378:2001+A1:2013 | Pasta processing plants - Pasta presses - Safety and hygiene requirements |
| EN 50525-2-81:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding |
| EN 60702-1:2002/A1:2015 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015) |
| EN 50382-1 : 2008 AMD 1 2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
| EN 50525-2-71:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation |
| EN 50264-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements |
| HD 60364-5-56:2010/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES |
| HD 22.13 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
| EN 50525-3-31:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke |
| HD 60364-5-52:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS |
| BS EN 50174-3 : 2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
| EN 50264-3-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
| BS EN 50396 : 2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
| BS EN 50174-2 : 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
| EN 13289:2001+A1:2013 | Pasta processing plants - Dryers and coolers - Safety and hygiene requirements |
| EN 13501-6:2014 | Fire classification of construction products and building elements - Part 6: Classification using data from reaction to fire tests on electric cables |
| BS EN 13378 : 2001 | PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS |
| BS EN 60695-1-10:2017 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. General guidelines |
| HD 22.12 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES |
| HD 22.16 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES |
| EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| I.S. EN 13379:2001 | PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS |
| BS EN 50525-3-21:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke |
| I.S. EN 13378:2001 | PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS |
| BS EN 50525-2-31:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with thermoplastic PVC insulation |
| BS EN 50525-2-41:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core cables with crosslinked silicone rubber insulation |
| BS EN 50525-3-11:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
| BS EN 50525-2-81:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric covering for arc welding |
| BS EN 50525-2-83:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Multicore cables with crosslinked silicone rubber insulation |
| BS EN 50525-3-41:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
| BS EN 1710 : 2005 | EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES |
| I.S. EN 13289:2001 | PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS |
| BS EN 50525-2-51:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Oil resistant control cables with thermoplastic PVC insulation |
| BS EN 50525-2-72:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat divisible cables (cords) with thermoplastic PVC insulation |
| BS EN 50525-2-82:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Cables with crosslinked elastomeric insulation for decorative chains |
| I.S. HD 60364-5-56:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES (IEC 60364-5-56:2009 (EQV)) |
| I.S. EN 50620:2017 | ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES |
| DIN EN 13289:2013-05 | PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS |
| DIN EN 13501-6:2014-07 | FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES |
| BS EN 50174-1 : 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| BS EN 50618:2014 | Electric cables for photovoltaic systems (BT(DE/NOT)258) |
| BS EN 1889-1:2011 | Machines for underground mines. Mobile machines working underground. Safety Rubber tyred vehicles |
| BS EN 50525-2-11:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750V (U0/U) Cables for general applications. Flexible cables with thermoplastic PVC insulation |
| BS EN 50525-2-71:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flat tinsel cables (cords) with thermoplastic PVC insulation |
| BS EN 62368-1 : 2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
| BS EN 50441-2:2012 | Cables for indoor residential telecommunication installations Screened cables. Grade 1 |
| BS EN 50441-1:2012 | Cables for indoor residential telecommunication installations Unscreened cables. Grade 1 |
| BS EN 50441-4:2012 | Cables for indoor residential telecommunication installations Cables up to 1 200 MHz. Grade 3 |
| BS EN 12601:2010 | Reciprocating internal combustion engine driven generating sets. Safety |
| BS EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1000 V but not exceeding 10000 V |
| BS EN 60695-9-2:2014 | Fire hazard testing Surface spread of flame. Summary and relevance of test methods |
| BS EN 50264-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance General requirements |
| BS EN 50525-3-31:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke |
| DD CEN/TS 45545-2:2009 | Railway applications. Fire protection on railway vehicles Requirements for fire behaviour of materials and components |
| I.S. EN 1889-1:2011 | MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
| I.S. EN 50174-2:2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
| CEI EN 50620 : 1ED 2017 | ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES |
| I.S. HD 60364-7-717:2010 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS |
| I.S. EN 61010-1:2010/A1:2019 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
| 04/30109460 DC : DRAFT FEB 2004 | HD 22.16 S2 - WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES |
| I.S. HD 60364-5-52:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS |
| BS EN 50264-2-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables |
| I.S. EN 50525-2-11:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION |
| BS EN 50264-2-2:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables |
| 04/30109458 DC : DRAFT FEB 2004 | HD 22.15 S2 - MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER |
| BS EN 50264-3-2:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables |
| BS EN 50575 : 2014 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
| BS EN 50264-3-1:2008 | Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables |
| 04/30109444 DC : DRAFT FEB 2004 | HD 22.13 S2 - HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE |
| I.S. EN 12601:2010 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
| S.R. CEN/TS 45545-2:2009 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
| I.S. EN 50174-1:2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
| BS EN 45545-2 : 2013 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
| EN 50525-2-83:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation |
| EN 50525-2-41:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation |
| EN 62368-1:2014/AC:2017-03 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
| PD CLC/TS 50576:2016 | Electric cables - Extended application of test results for reaction to fire |
| BS EN 50214:2006 | Flat polyvinyl chloride sheathed flexible cables |
| EN 1889-1:2011 | Machines for underground mines - Mobile machines working underground - Safety - Part 1: Rubber tyred vehicles |
| BS EN 50525-2-21:2011 | Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Flexible cables with crosslinked elastomeric insulation |
| NF EN 50396:2005 AMD 1 2012 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
| I.S. HD 60364-7-721:2009 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-721: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - ELECTRICAL INSTALLATIONS IN CARAVANS AND MOTOR CARAVANS |
| I.S. EN 62368-1:2014 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS (IEC 62368-1:2014, MODIFIED) |
| DIN EN 13289:2015-12 (Draft) | Pasta processing plant - Dryers and coolers - Safety and hygiene requirements; German and English version prEN 13289:2015 |
| BS EN 60079-35-1:2011 | Household and similar electrical appliances - Safety - Part 2-82: Particular requirements for amusement machines and personal service machines |
| HD 22.15 : 200S2 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER |
| BS EN 13379 : 2001 | PASTA PROCESSING PLANTS - SPREADER, STRIPPING AND CUTTING MACHINE, STICK RETURN CONVEYOR, STICK MAGAZINE - SAFETY AND HYGIENE REQUIREMENTS |
| BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
| BS EN 50382-1 : 2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
| BS EN 13289 : 2001 | PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS |
| DIN EN 1710:2008-08 | EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES |
| DIN EN 1889-1:2011-10 | MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES |
| 16/30337092 DC | BS EN 13378. Pasta processing plant. Pasta presses. Safety and hygiene requirements |
| HD 22-9 : 200S3 | CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE |
| EN 50143:2009 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
| DIN EN 45545-2:2016-02 | RAILWAY APPLICATIONS - FIRE PROTECTION ON RAILWAY VEHICLES - PART 2: REQUIREMENTS FOR FIRE BEHAVIOUR OF MATERIALS AND COMPONENTS |
| BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
| CEN/TS 45545-2:2009 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behaviour of materials and components |
| EN 50264-2-2:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
| EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
| EN 50264-3-1:2008 | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
| EN 50628:2016 | Erection of electrical installations in underground mines |
| EN 50382-2:2008/A1:2013 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
| EN 50214:2006/corrigendum Dec. 2007 | FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES |
| EN 50396 : 2005 AMD 1 2011 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
| EN 50525-2-82:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains |
| EN 50525-3-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
| CLC/TS 50576:2016 | Electric cables - Extended application of test results for reaction to fire |
| EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
| EN 60079-35-1:2011/AC:2011 | EXPLOSIVE ATMOSPHERES - PART 35-1: CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - GENERAL REQUIREMENTS - CONSTRUCTION AND TESTING IN RELATION TO THE RISK OF EXPLOSION |
| EN 50525-3-41:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
| EN 50525-2-11:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation |
| EN 50618:2014 | Electric cables for photovoltaic systems |
| EN 50441-2:2012 | Cables for indoor residential telecommunication installations - Part 2: Screened cables - Grade 1 |
| EN 50525-2-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
| UNE-EN 50525-2-51:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation |
| UNE-EN 50525-3-41:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
| I.S. EN 50396:2005 | NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES |
| I.S. EN 50525-3-21:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
| UNE-EN 50525-2-82:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains |
| I.S. EN 60079-35-1:2011 | EXPLOSIVE ATMOSPHERES - PART 35-1: CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - GENERAL REQUIREMENTS - CONSTRUCTION AND TESTING IN RELATION TO THE RISK OF EXPLOSION |
| UNE-EN 60079-35-1:2012 | Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion |
| UNE-EN 50525-2-31:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation |
| UNE-EN 50264-2-2:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables |
| UNE-EN 50264-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements |
| I.S. EN 50382-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
| I.S. EN 60332-1-3:2004 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES |
| I.S. EN 1710:2005 | EQUIPMENT AND COMPONENTS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES |
| UNE-EN 50525-3-21:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke |
| UNE-EN 50264-2-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables |
| I.S. EN 50382-2:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C |
| UNE-EN 50525-2-83:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation |
| I.S. EN 60702-1:2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
| I.S. EN 50525-2-21:2011 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
| UNE-EN 50264-3-1:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables |
| UNE-EN 50525-2-11:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation |
| UNE-EN 50525-2-72:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation |
| UNE-EN 50525-2-21:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation |
| UNE-EN 50525-2-81:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding |
| UNE-EN 50525-2-71:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation |
| UNE-EN 50525-3-11:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
| UNE-EN 50264-3-2:2010 | Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
| UNE-EN 50525-2-41:2012 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation |
| UNE-EN 45545-2:2013 | Railway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components |
| EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
| UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
| EA 0051:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
| UNE-EN 50143:2010 | Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V |
| UNE-HD 60364-7-717:2013 | Low-voltage electrical installations -- Part 7-717: Requirements for special installations or locations - Mobile or transportable units |
| UNE-EN 12601:2011 | Reciprocating internal combustion engine driven generating sets - Safety |
| UNE-HD 60364-5-56:2010 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services |
| UNE-EN 60332-2-2:2005 | Tests on electric and optical fibre cables under fire conditions -- Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
| UNE-EN 50618:2015 | Electric cables for photovoltaic systems |
| UNE-EN 50575:2015 | Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements |
| UNE-HD 60364-7-721:2011 | Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans |
| UNE-EN 1889-1:2012 | Machines for underground mines - Mobile machines working underground - Safety - Part 1: Rubber tyred vehicles |
| UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
| CEI EN 50525-2-41 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION |
| CEI EN 50525-3-11 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
| CEI EN 50174-3 : 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
| CEI EN 50441-2 : 2013 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1 |
| CEI EN 50264-2-2 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES |
| CEI EN 50264-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
| CEI EN 50143 : 2012 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
| CEI EN 50525-2-82 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS |
| CEI EN 50441-4 : 2013 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3 |
| UNE-CLC/TS 50576:2017 | Electric cables - Extended application of test results for reaction to fire |
| CEI EN 50628 : 1ED 2017 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
| UNE-HD 620-1:2010 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements. |
| CEI CLC/TS 50576 : 2015 | ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE |
| UNE-EN 60332-1-1:2005 | Tests on electric and optical fibre cables under fire conditions -- Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus |
| UNE-EN 61010-1:2011 | Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 1: General requirements |
| CEI EN 50525-2-72 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION |
| CEI EN 50525-3-41 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
| CEI EN 60079-35-1 : 2012 | EXPLOSIVE ATMOSPHERES - PART 35-1: CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - GENERAL REQUIREMENTS - CONSTRUCTION AND TESTING IN RELATION TO THE RISK OF EXPLOSION |
| CEI EN 50525-2-71 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION |
| CEI EN 50264-3-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES |
| CEI EN 50525-2-51 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION |
| CEI EN 50525-2-31 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION |
| CEI EN 50525-3-31 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE |
| UNE-EN 50620:2017 | Electric cables - Charging cables for electric vehicles |
| CEI EN 50525-2-83 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION |
| CEI EN 50264-2-1 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES |
| UNE-EN 60079-14:2016 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
| UNE-EN 60695-1-10:2017 | Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
| CEI EN 62368-1 : 2016 | AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS |
| CEI EN 50525-2-11 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-11: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH THERMOPLASTIC PVC INSULATION |
| CEI EN 50264-3-2 : 2009 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES |
| CEI EN 50525-3-21 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
| CEI 20-60 : 1999 | POWER CABLES HAVING RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO INCLUDING 20,8/36 (42) KV |
| UNE-HD 60364-5-52:2014 | Low-voltage electrical installations -- Part 5-52: Selection and erection of electrical equipment - Wiring systems |
| CEI EN 50525-2-21 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
| CEI EN 50525-2-81 : 2012 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING |
| CEI 20-66 : 2010 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
| CEI EN 50441-1 : 2013 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1 |
| I.S. EN 50575:2014 | POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS |
| I.S. EN 50441-2:2012 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1 |
| I.S. EN 50441-1:2012 | CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 1: UNSCREENED CABLES - GRADE 1 |
| I.S. HD 627:2003 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
| I.S. EN 50264-1:2008 | RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS |
| S.R. CLC/TS 50576:2016 | ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE |
| I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
| I.S. EN 50214:2007 | FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES |
| CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
| I.S. HD 603:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
| CEI EN 50214 : 2007 | FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES |
| I.S. EN 50143:2009 | CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V |
| I.S. EN 50174-3:2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
| DIN EN 12601:2011-07 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY |
| BS EN 50628:2016 | Erection of electrical installations in underground mines |
| S.R. HD 60364-5-52:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS |
| I.S. EN 60079-14:2014 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
| IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
| IEC 60332-1-3:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles |
| IEC 60332-2-2:2004 | Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame |
| ISO 13943:2017 | Fire safety — Vocabulary |
| IEC 60811-203:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions |
| IEC 60332-1-1:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus |
| EN 60332-1-1:2004/A1:2015 | Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus |
| EN 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
| IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
| EN 60811-203:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions |
Summarise
Sorry this product is not available in your region.