ISA TR12.21.01 : 2004
Withdrawn
USE OF FIBER OPTIC SYSTEMS IN CLASS 1 HAZARDOUS (CLASSIFIED) LOCATIONS
English
01-01-2004
03-19-2018
Foreword
Abstract
Key Words
1 Scope
2 Purpose
3 Definitions and figures
4 Introduction
5 Optical ignition characteristics
6 Protection concepts
7 Installation and maintenance
8 References
Describes guidance on the safe use of fiber optic systems and their constituent parts producing or guiding visible, near infrared, or mid infrared (maximum wavelength of 10 [mu]m) radiation in Class 1 hazardous (classified) locations.
| DocumentType |
Standard
|
| Pages |
30
|
| PublisherName |
International Society of Automation
|
| Status |
Withdrawn
|
| API 14FZ : 2013 | RECOMMENDED PRACTICE FOR DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, ZONE 0, ZONE 1, AND ZONE 2 LOCATIONS |
| EN 60079-28:2015 | Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation |
| I.S. EN 60079-28:2015 | EXPLOSIVE ATMOSPHERES - PART 28: PROTECTION OF EQUIPMENT AND TRANSMISSION SYSTEMS USING OPTICAL RADIATION |
| C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
| C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
| API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| BS EN 60079-28:2015 | Explosive atmospheres Protection of equipment and transmission systems using optical radiation |
| API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| UNE-EN 60079-28:2016 | Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation |
| IEC 60794-3:2014 | Optical fibre cables - Part 3: Outdoor cables - Sectional specification |
| IEC 60825-2:2004+AMD1:2006+AMD2:2010 CSV | Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCS) |
| ISA 12.01.01 : 2009 | DEFINITIONS AND INFORMATION PERTAINING TO ELECTRICAL EQUIPMENT IN HAZARDOUS (CLASSIFIED) LOCATIONS |
| IEC 60050-731:1991 | International Electrotechnical Vocabulary (IEV) - Part 731: Optical fibre communication |
| IEC TR 60079-20:1996 | Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus |
| IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
| IEC 60794-1:1996 | Optical fibre cables - Part1: Generic specification (Revision to IEC 794-1) |
| IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
| IEC 60825-1:2014 | Safety of laser products - Part 1: Equipment classification and requirements |
| ISA 84.01 : 1996 | APPLICATION OF SAFETY INSTRUMENTED SYSTEMS FOR THE PROCESS INDUSTRIES |
| IEC 60794-4:2003 | Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines |
| ISA 12.00.01 : 2002 | ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 0, 1 AND 2 HAZARDOUS (CLASSIFIED) LOCATIONS - GENERAL REQUIREMENTS |
| NFPA 115 : 2016 | LASER FIRE PROTECTION |
| NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
| IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
| IEC 60794-2:2017 | Optical fibre cables - Part 2: Indoor cables - Sectional specification |
| NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |