• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

14/30303365 DC : 0

NA

NA

Status of Standard is Unknown

BS ISO/ASTM 51649 - PRACTICE FOR DOSIMETRY IN AN ELECTRON BEAM FACILITY FOR RADIATION PROCESSING AT ENERGIES BETWEEN 300 KEV AND 25 MEV

Available format(s)

Hardcopy , PDF

Language(s)

English

£20.00
Excluding VAT

1 Scope
2 Referenced documents
3 Terminology
4 Significance and use
5 Radiation source characteristics
6 Documentation
7 Dosimetry system selection and calibration
8 Installation qualification
9 Operational qualification
10 Performance qualification
11 Routine process control
12 Certification
13 Measurement uncertainty
14 Keywords
ANNEXES (informative) -
A1 - TYPES OF ELECTRON BEAM FACILITIES
A2 - ELECTRON BEAM DEPTH-DOSE DISTRIBUTIONS
A3 - MEASUREMENT OF DEPTH-DOSE DISTRIBUTION
A4 - CALCULATION OF ELECTRON BEAM ENERGY BASED
     ON MEASURED DEPTH-DOSE DISTRIBUTION
A5 - ABSORBED DOSE AS FUNCTION OF BEAM CURRENT,
     BEAM WIDTH AND CONVEYOR SPEED
A6 - MEASUREMENT OF BEAM WIDTH AND DOSE UNIFORMITY
     ALONG SCAN DIRECTION
A7 - DOSE DISTRIBUTIONS FOR SCANNED AND PULSED BEAMS
A8 - DOSE DISTRIBUTION IN REFERENCE MATERIAL
A9 - PROCESS INTERRUPTION
A10 - MATERIAL PROCESSING RATES
A11 - TABLE A2 FROM ISO 11137-1
Bibliography

BS ISO/ASTM 51649.

Committee
NCE/2
DocumentType
Draft
Pages
44
PublisherName
British Standards Institution
Status
NA

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 11137-1:2006 Sterilization of health care products — Radiation — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO/ASTM 51702:2013 Practice for dosimetry in a gamma facility for radiation processing
ISO/ASTM 51818:2013 Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV
ISO/ASTM 51261:2013 Practice for calibration of routine dosimetry systems for radiation processing
ISO/ASTM 51275:2013 Practice for use of a radiochromic film dosimetry system
ISO/ASTM 51608:2015 Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV
ASTM F 1356 : 2016 : REDLINE Standard Guide for Irradiation of Fresh, Frozen or Processed Meat and Poultry to Control Pathogens and Other Microorganisms
ASTM E 170 : 2017 : REDLINE Standard Terminology Relating to Radiation Measurements and Dosimetry
ASTM E 2232 : 2016 : REDLINE Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications
ISO/ASTM 51539:2013 Guide for use of radiation-sensitive indicators
ISO/ASTM 52701:2013 Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing
ISO 14470:2011 Food irradiation — Requirements for the development, validation and routine control of the process of irradiation using ionizing radiation for the treatment of food
ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
ISO/ASTM 51707:2015 Guide for estimation of measurement uncertainty in dosimetry for radiation processing
ISO/ASTM 52628:2013 Standard practice for dosimetry in radiation processing
ASTM E 2303 : 2015 : REDLINE Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

£20.00
Excluding VAT