1 Scope and object
2 Terms and definitions
3 Classification and levels
4 Apparatus and material
5 Procedure
6 Failure criteria
7 Summary
Annex A (informative) - Examples of special pins
        that are connected to passive components
Annex B (informative) - Calculation of operating
        ambient or operating case temperature for
        a given operating junction temperature

Specifies the I-test and the overvoltage latch-up testing of integrated circuits. It establishes a method for determining integrated circuit latch-up characteristics and to define latch-up failure criteria.

Committee
EPL/47
DevelopmentNote
Supersedes 02/205138 DC (03/2004) Supersedes 09/30209746 DC. (09/2011)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC 60749 covers the I-test and the overvoltage latch-up testing of integrated circuits.

This test is classified as destructive.

The purpose of this test is to establish a method for determining integrated circuit (IC) latch-up characteristics and to define latch-up failure criteria. Latch-up characteristics are used in determining product reliability and minimizing \'no trouble found\' (NTF) and \'electrical overstress\' (EOS) failures due to latch-up.

This test method is primarily applicable to CMOS devices. Applicability to other technologies must be established.

The classification of latch-up as a function of temperature is defined in 3.1 and the failure level criteria are defined in 3.2