• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

NF EN 60603-7-3 : DEC 2010

Current

Current

The latest, up-to-date edition.

CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-3: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 100 MHZ

Published date

12-01-2013

Sorry this product is not available in your region.

Avant-propos
INTRODUCTION
1 Généralités
2 Désignation de type CEI
3 Caractéristiques communes et vue isométrique
4 Sorties de câble et connexions internes - embases
  et fiches
5 Calibres
6 Caractéristiques
7 Essais et programmes d'essai
Annexe A (normative) - Procédure d'essai de la continuité
         de calibrage
Annexe B (normative) - Fonctionnement mécanique du
         dispositif de verrouillage
Annexe C (normative) - Exigences pour la fiche d'essai
Annexe D (normative) - Exigences générales pour le
         montage de mesure
Annexe E (normative) - Perte d'insertion
Annexe F (normative) - Affaiblissement de réflexion
Annexe G (normative) - Paradiaphonie (NEXT)
Annexe H (normative) - Télédiaphonie (FEXT)
Annexe I (normative) - Impédance de transfert
Annexe J (normative) - Perte de conversion transverse
         (TCL) et perte de transfert de conversion
         transverse (TCTL)
Annexe K (normative) - Sortie de symétriseur
Annexe L (normative) - Exigences de calibre
Bibliographie
Annexe ZA (normative) - Références normatives à
          d'autres publications internationales avec
          les publications européennes correspondantes

Cette partie de la CEI 60603 couvre les fiches et les embases blindées à 8 voies et spécifie les exigences mécaniques et environnementales ainsi que les exigences de transmission électrique pour des fréquences jusqu'à 100 MHz.

DevelopmentNote
Indice de classement: C93-430-7-3. PR NF EN 60603-7-3 November 2006. (11/2006) PR NF EN 60603-7-3 March 2010. (03/2010)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

Standards Relationship
EN 60603-7-3:2010 Identical
IEC 60603-7-3:2010 Identical

NF EN 60512-26-100 : 2009 AMD 1 2011 CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 26-100: MEASUREMENT SETUP, TEST AND REFERENCE ARRANGEMENTS AND MEASUREMENTS FOR CONNECTORS ACCORDING TO IEC 60603-7 - TESTS 26A TO 26G
UTEC 93 586-2 : 2012 CABLAGES DE TELECOMMUNICATIONS SYMETRIQUES SELON LA SERIE NF EN 50173 - CORDONS DROITS DE BRASSAGE ET CORDONS DROITS DE ZONE DE TRAVAIL ECRANTES POUR LES APPLICATIONS DE CLASSE D - SPECIFICATION PARTICULIERE
UTEC 90 483 : 2007 RESIDENTIAL CABLING OF COMMUNICATION NETWORKS
NF EN 61076-3-116 : 2009 CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER
UTEC 93 431 : 2011 INTERNAL TERMINAL DEVICE WITH INTERFACE OF CONNECTION IN T OR RJ45.DTI - PRODUCT SPECIFICATION

IEC 61076-1:2006 Connectors for electronic equipment - Product requirements - Part 1: Generic specification
IEC 60352-3:1993 Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance
IEC 60352-6:1997 Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
ISO/IEC 11801:2002 Information technology — Generic cabling for customer premises
IEC 60068-2-38:2009 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
ISO 1302:2002 Geometrical Product Specifications (GPS) — Indication of surface texture in technical product documentation
IEC 61156-2:2010 Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification
IEC 60603-7:2008+AMD1:2011 CSV Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors
IEC 60352-5:2012 Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance
IEC 60512-1-100:2012 Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications
IEC 61156-1:2007+AMD1:2009 CSV Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification
IEC 60352-2:2006+AMD1:2013 CSV Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance
IEC 61156-5:2009+AMD1:2012 CSV Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification
IEC 61156-4:2009 Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification
IEC 61156-3:2008 Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification
EN 50289-1-14:2004 Communication cables - Specifications for test methods - Part 1-14: Electrical test methods - Coupling attenuation or screening attenuation of connecting hardware
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60050-581:2008 International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment
IEC 60352-7:2002 Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance

Sorry this product is not available in your region.